Part Number Hot Search : 
MAX6604 TEA2025 N74F14N H087B GRM31CR6 X40414 A51A46F XXXJX
Product Description
Full Text Search
 

To Download 44HS30-02-1-12N Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  grayhill, inc. ? 561 hillgrove avenue ? lagrange, illinois 60525-5997 ? usa ? phone: 708-354-1040 ? fax: 708-354-2820 ? www.gr ayhill.com rotary switches special function rotary switches dimensions specifications electrical ratings the switching elements, and therefore ratings, are the same in an isolated position switch as in a conventional rotary switch. mechanical life is also the same. additional characteristics shaft movement or vertical travel: series 09 .062 .020 (1,57 0,51) series 42 & 44 .070 .020 (1,78 0,51) series 50 & 51 .080 .020 (2,03 0,51) push or pull force required: series 09 1.75 .5 lbs series 42 & 44 2 .5 lbs series 50 & 51 2 .5 lbs stops: single pole per deck switches with the maximum number of positions are supplied with stops only on request: 12 positions in 30 throw, 10 in 36, and 8 in 45. stop strength: approximately 7.5 pound-inches for the isolated position stop. features  protected switch positions for safety, calibration, or stand-by  choice of push- or pull-to-turn  1 / 2 " diameter, 200 ma and 1" diameter, 1 amp switch  10,000 cycles of operation series 09 series 42 & 44 series 50 & 51 dimension a 1 deck 1.371 (34,82) 2 decks 1.717 (43,61) 3 decks 2.063 (52,40) 4 decks 2.409 (61,19) dimension a 1 deck 1.228 (31,19) 2 decks 1.496 (38,0) 3 decks 1.764 (44,81) 4 decks 2.032 (51,61) dimension a solder lug .893 .025 (22,68 0,64) pc style .897 .025 (22,78 0,64) grayhill part number and date code marked on label. customer number marked on request. description an isolated position is one which cannot be reached by the normal rotation. an additional action is required by the operator. it could be either push-to-turn, or pull-to-turn. after the switch is rotated to the isolated position, releasing the shaft locks the switch in that position. push or pull again to rotate the switch again. use isolated positions to protect a switch position from indiscriminate rotation. such safety positions might include ?calibrate?, ?off? and/or ?stand-by?. external differences the isolated position mechanism increases the depth of the series 50 and 51 by 0.217" (5,51 mm). all other dimensions remain unchanged. in series 9, 42 and 44, it has the appearance of an additional deck section without terminals, located directly behind the detent system. materials and finishes materials and finishes for the isolation mechanism are listed here. series 50 and 51 housing: zinc casting, tin/zinc-plated shaft: 303 stainless steel stop pin and stop post: 303 stainless steel spring: tinned music wire series 09 housing: phenolic for style a; diallyl, for m shaft: 303 stainless steel, electro-polished stop pin and stop post: 303 stainless steel spring: tinned music wire series 42 and 44 housing: diallyl per mil-m-14 shaft: 303 stainless steel lock plate: 302 stainless steel lock arm: 316 stainless steel lock post: brass, tin/zinc-plated compression spring: tinned music wire series 09, 42, 44, 50, 51 isolated position rotary 4 dim . a + . 046 (1 , 17) ?.020 (0,51) .062 (1,57) dim. a solder lugs dim. a pc terminals dim. a + .046 ?.020 (+ 0,05 ?0,51)
grayhill, inc. ? 561 hillgrove avenue ? lagrange, illinois 60525-5997 ? usa ? phone: 708-354-1040 ? fax: 708-354-2820 ? www.gr ayhill.com rotary switches conventional numbers start by creating a conventional switch number in the manner which follows: series & style angle of throw number of decks 09a30-01-1-12n type of contacts shorting = s non-shorting = n positions per pole poles per deck note: no stop arrangement suffix is needed. see describing stops. special function rotary switches standard military style angle of no. of poles per positions shorting or style style** description throw decks deck per pole non-shorting 01 to 04 1 02 to 12 n or s 01 to 04 2 02 to 06 n or s 09a 09m solder lug 30 01 to 04 3 02 to 04 n or s 01 to 04 4 02 or 03 n or s 01 to 04 5 02 n or s 01 to 03 6 02 n or s 42a 42m solder lug 42s ? sealed 36 01 to 04 1 02 to 10 n or s ? 42h 125 temperature rating 01 to 04 2 02 to 05 n or s ? 42hs 125 temp rating, sealed 01 to 04 1 02 to 12 n or s 01 to 04 2 02 to 06 n or s 30 01 to 04 3 02 to 04 n or s 44a 44m solder lug 01 to 04 4 02 or 03 n or s 44s ? sealed 01 to 04 5 02 n or s ? 44h 125 temperature rating 01 to 04 6 02 n or s ? 44hs 125 temp rating, sealed 45 01 to 04 1 02 to 08 n or s 01 to 03 2 02 to 04 n or s 01 or 02 3 02 n or s 01 or 02 4 02 n -- 50c solder lug -- 50cp pc mount 36 01 1 02 to 10 n or s -- 50m* solder lug, sealed 2 02 to 05 n or s -- 50mp* sealed, pc -- 51c solder lug 1 02 to 12 n or s -- 51cp pc mount 30 01 2 02 to 06 n or s -- 51m* solder lug, sealed 3 02 or 03 n or s -- 51mp* pc mount, sealed 4 02 or 03 n or s *(pull-to-turn only) **for specifics on military qualified products, see standard switch pages. choices and limitations describing stops when a 1-pole switch has less than the maximum number of positions, consider also the stop system. following is the arrangement for a 6 position switch with the position 1 isolated. stop 1p2 3 4 5 6 stop the word ?stop? indicates the conventional switch stops, which limit rotation to positions 1 through 6. to isolate position 1 we insert only one isolation post?between terminals 1 and 2. the stop system already prevents rotation beyond terminal 1. in multi-pole switches, the stop system and isolation system described for the first pole, automatically affects the other poles. in the example above, isolating position #1 on the first pole isolates the first position (terminal #7) of the second pole. see standard switch pages for a 2 pole circuit diagram for a 30 throw switch. let's isolate position 1 and position 2 from all other positions and from each other. we indicate isolation posts as shown here: 12p1p2p3 4 5 6 7 8 9 10 11 12 to isolate just position 1, describe like this: 12p1p2 3 4 5 6 7 8 9 10 11 12 to isolate positions 1 and 2 from all other positions, but not from each other, do this: 12p1 2p3 4 5 6 7 8 9 10 11 12 ordering information indicate this as a special switch to ensure that no error is made when the order is entered. sample part number: special 09a30-04-1-12n pull 12p1p2p3 4 5 6 7 8 9 10 11 12 this sample part number orders a series 9 standard style, four deck, one pole per deck, twelve positions per pole rotary switch with non- shorting contacts and isolation posts between positions 12 and 1, between 1 and 2, and between 2 and 3. this lengthy order number is required to prevent any possible confusion in ordering the switch. when we receive your order, we will assign a special ?short form? part number to facilitate future identification of this special switch. this number is sequentially assigned as the need arises, and is non-descriptive. a typical ?short form? special part number might be 09yy12345. contact grayhill for price. not available through distributors. describing positions the grayhill system for isolating positions lets you choose the positions to be isolated. grayhill inserts isolation posts next to the positions to be isolated. consider a continuous rotation switch of the series 09a with a 30 angle of throw. the terminals are listed here from 1 through 12 with a space between each to indicate where isolation posts might be inserted. 12123456789101112 rotary 5


▲Up To Search▲   

 
Price & Availability of 44HS30-02-1-12N

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X